Basic Information Overview

  • Category: Integrated Circuit (IC)
  • Use: Voltage Supervisor
  • Characteristics: Low-power, Precision, Reset Output
  • Package: Small Outline Integrated Circuit (SOIC)
  • Essence: Monitors the power supply voltage and generates a reset signal when the voltage falls below a predetermined threshold.
  • Packaging/Quantity: Tape and Reel, 2500 pieces per reel

Specifications

  • Supply Voltage Range: 1.0V to 5.5V
  • Operating Temperature Range: -40°C to +85°C
  • Reset Threshold Voltage Options: 2.63V, 3.08V, 4.38V
  • Reset Timeout Period Options: 140ms, 280ms, 560ms, 1120ms
  • Quiescent Current: 10µA (typical)

Detailed Pin Configuration

The MAX706CSA+TG126 has a total of 8 pins: 1. GND: Ground 2. RESET: Active-Low Reset Output 3. MR: Manual Reset Input 4. VCC: Positive Power Supply 5. TH: Threshold Input 6. CT: Capacitor Connection for Reset Timeout 7. RESET: Active-Low Reset Output 8. VCC: Positive Power Supply

Functional Features

  • Monitors the power supply voltage and generates a reset signal when the voltage drops below the set threshold.
  • Provides a manual reset input for external reset control.
  • Offers multiple options for reset threshold voltage and timeout period.
  • Low quiescent current consumption makes it suitable for battery-powered applications.

Advantages

  • Precise monitoring of power supply voltage ensures reliable system operation.
  • Flexible configuration options allow customization based on specific requirements.
  • Low-power consumption extends battery life in portable devices.
  • Small package size saves board space in compact designs.

Disadvantages

  • Limited reset timeout period options may not suit all applications.
  • Requires an external capacitor for reset timeout functionality.

Working Principles

The MAX706CSA+TG126 operates by comparing the power supply voltage with a preset threshold voltage. When the voltage falls below the threshold, the reset output is activated. The reset signal remains active until the voltage rises above the threshold or a manual reset input is triggered. The reset timeout period determines how long the reset signal remains active after the voltage returns to normal.

Detailed Application Field Plans

The MAX706CSA+TG126 is commonly used in various electronic systems where reliable power supply monitoring and reset functionality are crucial. Some application fields include: - Microcontrollers and microprocessors - Embedded systems - Industrial control systems - Automotive electronics - Medical devices

Detailed and Complete Alternative Models

  1. MAX705CSA+TG126: Similar to MAX706CSA+TG126 but with different reset threshold voltage options.
  2. MAX707CSA+TG126: Voltage supervisor with additional features like watchdog timer and adjustable reset timeout.
  3. MAX708CSA+TG126: Voltage supervisor with higher supply voltage range and wider temperature range.

(Note: This list is not exhaustive and there may be other alternative models available from different manufacturers.)

Word count: 346 words

Noem 10 veelgestelde vragen en antwoorden met betrekking tot de toepassing van MAX706CSA+TG126 in technische oplossingen

Sure! Here are 10 common questions and answers related to the application of MAX706CSA+TG126 in technical solutions:

  1. Q: What is the purpose of MAX706CSA+TG126? A: MAX706CSA+TG126 is a voltage detector and reset IC that monitors the power supply voltage and generates a reset signal when the voltage falls below a certain threshold.

  2. Q: What is the operating voltage range of MAX706CSA+TG126? A: The operating voltage range of MAX706CSA+TG126 is typically between 1.0V and 5.5V.

  3. Q: How does MAX706CSA+TG126 generate a reset signal? A: MAX706CSA+TG126 generates a reset signal by pulling the RESET output pin low when the monitored voltage drops below the specified threshold.

  4. Q: Can I adjust the threshold voltage for generating the reset signal? A: No, the threshold voltage for generating the reset signal is fixed and cannot be adjusted in MAX706CSA+TG126.

  5. Q: What is the typical reset timeout period of MAX706CSA+TG126? A: The typical reset timeout period of MAX706CSA+TG126 is 140ms.

  6. Q: Can I use MAX706CSA+TG126 with both active-high and active-low reset signals? A: Yes, MAX706CSA+TG126 supports both active-high and active-low reset signals, depending on the configuration of the MR (Master Reset) pin.

  7. Q: Is MAX706CSA+TG126 suitable for battery-powered applications? A: Yes, MAX706CSA+TG126 is designed to operate in low-power applications and is suitable for battery-powered systems.

  8. Q: What is the maximum supply current of MAX706CSA+TG126? A: The maximum supply current of MAX706CSA+TG126 is typically 15µA.

  9. Q: Can I use MAX706CSA+TG126 in automotive applications? A: Yes, MAX706CSA+TG126 is qualified for automotive applications and meets the necessary standards.

  10. Q: Are there any specific precautions to consider when using MAX706CSA+TG126? A: It is important to ensure proper decoupling and bypassing of power supply pins, as well as following the recommended operating conditions and layout guidelines provided in the datasheet.

Please note that these answers are general and may vary depending on the specific requirements and application of MAX706CSA+TG126.