Afbeelding kan een representatie zijn.
Zie specificaties voor productdetails.
MAX706CSA+TG002

MAX706CSA+TG002

Product Overview

  • Category: Integrated Circuit (IC)
  • Use: Voltage Supervisor
  • Characteristics: Low-power, precision voltage monitoring
  • Package: Small Outline Integrated Circuit (SOIC)
  • Essence: Monitors the power supply voltage and provides a reset signal to the microcontroller or other digital system when the voltage drops below a certain threshold.
  • Packaging/Quantity: Tape and Reel, 2500 units per reel

Specifications

  • Supply Voltage Range: 1.2V to 5.5V
  • Reset Threshold Options: 4.63V, 4.38V, 4.00V, 3.08V, 2.93V, 2.63V, 2.32V, 2.06V
  • Reset Timeout Period: 140ms (min)
  • Operating Temperature Range: -40°C to +85°C
  • Output Type: Active-Low Push-Pull
  • Quiescent Current: 10µA (typical)

Detailed Pin Configuration

The MAX706CSA+TG002 has eight pins in a small outline integrated circuit (SOIC) package. The pin configuration is as follows:

  1. GND: Ground connection
  2. RESET: Active-low reset output
  3. MR: Manual reset input
  4. VCC: Positive supply voltage
  5. TH: Threshold voltage selection input
  6. RESET#: Complementary reset output
  7. NC: No connection
  8. CAP: Capacitor connection for reset timeout adjustment

Functional Features

  • Monitors the power supply voltage and generates a reset signal when the voltage falls below the selected threshold.
  • Provides a manual reset input for immediate system reset.
  • Offers multiple threshold voltage options for flexibility in different applications.
  • Includes a reset timeout period to ensure proper system initialization.
  • Low quiescent current consumption for power efficiency.

Advantages and Disadvantages

Advantages: - Precise voltage monitoring for reliable system operation. - Wide supply voltage range allows compatibility with various systems. - Small package size for space-constrained applications. - Low-power design for energy-efficient operation.

Disadvantages: - Limited threshold voltage options may not suit all voltage requirements. - Lack of adjustable reset timeout period may limit customization in certain applications.

Working Principles

The MAX706CSA+TG002 operates by continuously monitoring the power supply voltage. When the voltage drops below the selected threshold, it triggers the reset output to go low, indicating a system reset condition. The reset signal remains active until the voltage rises above the threshold and the reset timeout period elapses. The manual reset input allows for immediate system reset regardless of the monitored voltage level.

Detailed Application Field Plans

The MAX706CSA+TG002 is commonly used in various electronic systems where reliable voltage monitoring and system reset functionality are crucial. Some application fields include:

  1. Microcontroller-based Systems: Ensures proper initialization and reliable operation of microcontroller-based systems, preventing data corruption or erratic behavior during power fluctuations.
  2. Industrial Control Systems: Provides voltage supervision in industrial control systems, ensuring safe and stable operation of critical equipment.
  3. Automotive Electronics: Monitors the power supply voltage in automotive electronics, enabling proper functioning of vehicle control units and safety systems.
  4. Battery-Powered Devices: Protects battery-powered devices from undervoltage conditions, preventing damage to sensitive components and preserving battery life.

Detailed and Complete Alternative Models

  1. MAX705CSA+TG002: Similar to MAX706CSA+TG002 but with different reset threshold options.
  2. MAX707CSA+TG002: Voltage supervisor with adjustable reset timeout period.
  3. MAX708CSA+TG002: Voltage supervisor with additional power-fail detection feature.
  4. MAX809CSA+TG002: Microprocessor reset circuit with a fixed threshold voltage.

(Note: This is not an exhaustive list of alternative models. Please refer to the manufacturer's documentation for a complete list of alternatives.)

Word count: 515 words

Noem 10 veelgestelde vragen en antwoorden met betrekking tot de toepassing van MAX706CSA+TG002 in technische oplossingen

Sure! Here are 10 common questions and answers related to the application of MAX706CSA+TG002 in technical solutions:

  1. Q: What is the MAX706CSA+TG002?
    A: The MAX706CSA+TG002 is a microprocessor supervisory circuit that monitors the power supply voltage of a microcontroller or other digital systems.

  2. Q: What is the purpose of using the MAX706CSA+TG002 in a technical solution?
    A: The MAX706CSA+TG002 ensures reliable operation by monitoring the power supply voltage and resetting the microcontroller when the voltage falls below a specified threshold.

  3. Q: How does the MAX706CSA+TG002 work?
    A: The MAX706CSA+TG002 continuously monitors the power supply voltage and generates a reset signal when the voltage drops below a predetermined level, ensuring proper system initialization.

  4. Q: Can the MAX706CSA+TG002 be used with different microcontrollers?
    A: Yes, the MAX706CSA+TG002 can be used with a wide range of microcontrollers and digital systems that require voltage monitoring and reset functionality.

  5. Q: What is the operating voltage range of the MAX706CSA+TG002?
    A: The MAX706CSA+TG002 operates within a voltage range of 1.8V to 5.5V, making it suitable for various applications.

  6. Q: Does the MAX706CSA+TG002 have any adjustable parameters?
    A: Yes, the MAX706CSA+TG002 allows for adjustable reset thresholds and reset timeout periods, providing flexibility in different system requirements.

  7. Q: Can the MAX706CSA+TG002 be used in battery-powered applications?
    A: Yes, the low quiescent current consumption of the MAX706CSA+TG002 makes it suitable for battery-powered applications, helping to conserve power.

  8. Q: Does the MAX706CSA+TG002 have any built-in protection features?
    A: Yes, the MAX706CSA+TG002 includes features like a watchdog timer and a manual reset input to enhance system reliability and fault tolerance.

  9. Q: Can the MAX706CSA+TG002 be used in automotive applications?
    A: Yes, the MAX706CSA+TG002 is designed to meet automotive industry standards, making it suitable for use in automotive electronics.

  10. Q: Are there any application notes or reference designs available for the MAX706CSA+TG002?
    A: Yes, Maxim Integrated provides application notes and reference designs that can help users understand and implement the MAX706CSA+TG002 in their technical solutions effectively.

Please note that the answers provided here are general and may vary depending on specific requirements and datasheet specifications.